Flange ball valve KFL-C

Technical Description

The KFL-C ball valve consists of a 3-piece body, and from DN 100 onwards of a 2-piece body. Up to nominal size DN 80, the flange is screwed into the body. From nominal size DN 100 onwards, the two body parts are flanged together. The stem is blowout-proof and, from nominal size DN 32 onwards, is fitted with a double O-ring seal.
Ball valves with DVGW approval PN 40 are supplied with a hand gearbox from nominal size DN 150 onwards.

Technical Data

Design Type

25 – PN 10 to DIN EN 1092-1
26 – PN 16 to DIN EN 1092-1
27 – PN 25 to DIN EN 1092-1
28 – PN 40 to DIN EN 1092-1
29 – PN 63 to DIN EN 1092-1
34 – PN 100 to DIN EN 1092-1
35 – PN 160 to DIN EN 1092-1
36 – PN 250 to DIN EN 1092-1
37 – PN 320 to DIN EN 1092-1

Connection Types

DIN flange

Nominal diameter

DN 10-250

Material

Steel

Pressure Ratings

PN max. 320

Face-to-Face Dimensions

DIN EN 558 FTF basic series 1 (formerly: DIN 3202-1 series F1)

Approvals

Series 26: DVGW for gas (up to DN 125)
Series 27, 28: DVGW for gas (up to DN 100)
TÜV component mark
TA Luft

Temperature Range

Standard: -10°C to +90°C; DVGW -20°C to +60°C
On request: -50°C to +250°C

Application Range

Liquids: Fluid group 1 and 2 in accordance with PED 2014/68/EU Article 13
Gases: Fluid group 1 and 2 in accordance with PED 2014/68/EU Article 13
Resistance to the flow medium must always be ensured.

Other product categories

Product finder

Start your inquiry quickly and easily
with our product finder.

von Scheven – Applications
Always a step ahead

News. Info. Trade fair dates.

All the latest news from von Scheven.

All news from von Scheven at a glance: In our news section, we provide information on current developments, product innovations, and exciting insights into our ball valve manufacturing facility. Additionally, you will find all important trade fair dates and events here, where you can experience von Scheven personally.

Scroll to Top